Data Centres · Tier III/IV · Colocation

H₂S from the drain.
Corrosion on the PCB.
SLA at risk.

Hydrogen sulfide and other sulfide gases from the drain biofilm cause "creep corrosion" on the motherboard's gold contacts and silver solder joints. It appears months after the problem begins. Green Drain™ eliminates the H₂S source — a safety measure for uptime.

EN 1253ASSE 1072-2020ASHRAE TC9.9Aware of Tier III/IV
>99.9 %
H₂S and odours
Tier IV
Standard
5 years
Life
0
Maintenance
Problem & solution

What ASHRAE and Telcordia say.

The ASHRAE TC9.9 and Telcordia GR-63 guidelines recommend limits for corrosive gases in spaces housing IT equipment. If drain biofilm is not under control, actual values in the building can exceed those recommendations.

Without Green Drain™

  • H₂S above ASHRAE thresholds — G2/G3 classification exceeding IT equipment specifications
  • Creep corrosion on gold connectors — appears months after exposure
  • Silver solders and copper traces exposed to sulfides — reliability degradation
  • SLA violation due to hardware instability caused by the environment
  • Tier III/IV facilities require a documented plan for controlling the atmosphere within the space.

With Green Drain™

  • Mechanical one-way barrier — H₂S, SO₂ and CH₄ stay in the sewer
  • Helps maintain an ASHRAE TC9.9 G1 atmosphere
  • Resistant to temperatures up to 100 °C — compatible with hot aisles
  • Chemical-free — safe for sensitive IT equipment and cleanroom
  • Documentation for Tier III/IV revision — compliance with EN 1253 and ASSE 1072
Standards and framework

A sector with strict standards.

The ASHRAE TC9.9 guidelines and the Telcordia GR-63-CORE industry requirements set recommended limits for corrosive gases in spaces housing IT equipment. The Uptime Institute rates reliability from Tier I to Tier IV, and ANSI/TIA-942 further describes environmental requirements. These are industry guidelines and standards, not legislation. Separately, more customers are asking for their data to be hosted in Croatia — usually for contractual reasons and because of their own clients' requirements, rather than because the General Data Protection Regulation explicitly requires it.

ASHRAE TC9.9
Standard for Data Centre Atmosphere
Telcordia GR-63
CORE — telecommunications equipment
Tier I-IV
Uptime Institute reliability classification
EU GDPR
Regulation is driving local data centres — market growth
American National Standards Institute/Telecommunications Industry Association 942
Data Centre Standard — Environmental Controls
EN 1253
EU standard — also applies to DC P-traps
Data Sources and Regulatory Framework (2024–2025 data)

Statistical data were taken from official sources: State Statistical Office (data.dzs.hr) Croatian Institute of Public Health (hzjz.hr), Ministry of Labor, Pension System, Family and Social Policy (mrosp.gov.hr), Agency for Science and Higher Education (azvo.hr), Ministry of Tourism and Sports (mint.gov.hr). Regulatory framework: EUR-Lex for EU directives and regulations — Regulation (EU) 2017/745 (MDR), Regulation (EC) No 178/2002 (general principles of food law), Regulation (EC) No 852/2004 (food hygiene — HACCP obligation), Regulation (EC) No 1935/2004 and Regulation (EU) No 10/2011 (food contact materials), Regulation (EU) No 528/2012 (BPR), Directive 2014/34/EU (ATEX). Standards: EN 1253-1 (floor P-traps, water seal ≥50 mm), EN 1253 Parts 6/7/8 (gullies with a water seal below 50 mm, with mechanical closure, and combined types; 2023 editions), ASSE 1072-2020 (floor drain trap seal protection devices) and NSF/ANSI 2 (food equipment). HACCP International RG-04 is a private certification programme operated by HACCP International, not an official certification issued by a public authority. Tourism data taken from the DZS publication for H1 2025, healthcare data from the HZJZ report 2024, data for education from DZS publications for the 2023/2024 and 2024/2025 school years, data for nursing homes from the MROSP report, and announcements of EU-funded construction in 2025. Revision date: May 2026.

Implementation

Delivered through change management.

The data centre doesn't allow improvisation. Everything goes through formal change management and a maintenance window. Our installation takes 30 minutes per washroom.

01

Technical analysis

Data centre drainage system overview — where the P-traps are in relation to the machine room.

02

Pilot zone

Sanitary fixtures and corridor — 30 days, measurement of H₂S and SO₂.

03

Change management

Formal process — enters the maintenance schedule.

04

Implementation

Maintenance window — one per washroom every 30 minutes.

Model Recommendation

Recommendation per zone in the data centre.

Croatian data centres (Combis, A1, HT, Span, S&T, Altus IT, MainStream) are built to Tier II–IV standards. Sanitary and staff auxiliary rooms are built conventionally (50–58 mm). The mechanical zone, CRAC rooms, and UPS rooms are the technical side — required to withstand temperatures up to +60 °C in hot aisles.

Green Drain™ Recommended for your industry.

  • Sanitary facilities and staff auxiliary rooms (NOC)GD 2The most critical zone — H₂S from the toilets must not enter the machine room.
  • Technical basement and UPS roomsGD 3. ASHRAE TC9.9 G1 atmosphere (H₂S <10 ppb).
  • CRAC plant room and chiller zoneGD 4Condensation, resistance to damp, cold conditions.
  • Central grooves on the technical floorGD 5 or GD 6High volume of leakage from the HVAC system.
💬 Not sure of the exact size? Send us a photo of your sink drain — our technical team will respond with a written recommendation within the same business day, free of charge.
Check out Green Drain™ → Request a quote
GD 2
50–58 mm · sanitary, auxiliary space
GD 3
75–85 mm · technical basement, UPS
GD 4
102–110 mm · CRAC, chiller
GD 5
120–135 mm · central technical groove
GD 6
150–156 mm · main drainage channel
Questions

What we get asked most.

Will this document the Tier III/IV revision?

We are sending the technical documentation, the EN 1253 compatibility note and the ASSE 1072-2020 test report. The auditor is requesting proof that the risk of corrosive gases is controlled — the drainage system is part of that control.

Can we measure the effect?

Yes. Pre-installation and post-installation measurements of H₂S, SO₂, and CH₄ at strategic points in the area.

Complete solution

Three products.
One protection portfolio.

Green Drain™ doesn't work alone — for maximum drain control it's combined with GD Uri-Tabs™ (urinals) and GreenSwirl™ (drain unblocking).

Ready for Free audit?

We come to the site, map the drains, and provide a written recommendation — no cost, no obligation.